PRE420 Instruction Manual – rev. E Page 25
THD Spectrum at 10 KHz
02/19/07 11:09:3010 kHz FFT at 60 dB Gain, Output Level = +24 dBu, 0 dBr = +24 dBu
ColorSweep Trace Line Style Thick Data Axis Comment Cursor1 Cursor2
1 1 Red Solid 4 Fft.Ch.2 Ampl Left *-109.271 dBr A *-118.787 dBr A
-150
-100
-148
-146
-144
-142
-140
-138
-136
-134
-132
-130
-128
-126
-124
-122
-120
-118
-116
-114
-112
-110
-108
-106
-104
-102
-109.271
-118.787
d
B
r
A
2k 32k4k 6k 8k 10k 12k 14k 16k 18k 20k 22k 24k 26k 28k 30k
20.022k 30.0293k
Hz
The above FFT plot shows that the PRE420 has very little harmonic distortion at high frequencies.
The 10 kHz test tone is notched out with a THD analyzer to improve the resolution of the test. The
20-kHz 2
nd
-harmonic distortion measures better than -109 dB. The 30-kHz 3
rd
-harmonic distortion
measures better than -118 dB.